TiX870 |
TiX875 |
TiX880 |
TiX885 |
Detector |
IR Resolution |
640 × 480 |
SuperResolution |
- |
- |
Enhanced to 1280 × 960 pixels |
Enhanced to 1280 × 960 pixels |
Thermal Sensitivity* (* Under best case scenario) |
<35 mk="" 30="" c="" td=""> |
<30 mk="" 30="" c="" td=""> |
<25 mk="" 30="" c="" td=""> |
Field of View (FOV) |
25° × 19° |
Spatial Resolution (IFOV) |
0.68 mRad |
Digital Zoom |
1 to 25x |
1 to 35x |
Detector Type |
Focal Plane Array (FPA), Uncooled Infrared Detector |
Spectral Response |
8 to 14 um |
Lens Aperture |
F 1.0 |
Lens Recognition |
Auto |
Minimum Focus Distance |
0.2 m |
Focus System |
Auto/Manual |
Frame Rate |
9 Hz |
30 Hz |
9 Hz |
30 Hz |
Measurement and Analysis |
Temperature Range |
-40 °C to 700 °C |
-40 °C to 700 °C |
-40 °C to 1200 °C |
-40 °C to 1200 °C |
Temperature Measurement Range |
-40 °C to 150 °C |
-40 °C to 150 °C |
-40 °C to 150 °C |
-40 °C to 150 °C |
0 °C to 350 °C |
0 °C to 350 °C |
0 °C to 350 °C |
0 °C to 350 °C |
0 °C to 700 °C |
0 °C to 700 °C |
0 °C to 700 °C |
0 °C to 700 °C |
|
|
300 °C to 1200 °C |
300 °C to 1200 °C |
Temperature Accuracy |
±2 °C or ±2% of reading, whichever is greater (normal temperature, 23 °C typical) |
High/Low-Temperature Capture |
Yes |
Reference Temperature Compensation |
Yes. The full-screen and measurement mark temperature are displayed as the difference between the actual temperature and the fixed temperature |
Automatic Temperature Difference Calculation |
Calculation of the difference between measurement marks or between a measurement mark and the fixed reference temperature |
Custom Temperature Measurement Point |
10 points |
20 points |
10 points |
20 points |
Custom Temperature Measurement Area |
10 areas (circle or rectangle) |
20 areas (circle or rectangle) |
10 areas (circle or rectangle) |
20 areas (circle or rectangle) |
Line Temperature Measurement |
10 lines |
20 lines |
10 lines |
20 lines |
Temperature Measurement Methods |
The highest and lowest temperature can be set within an area, and the highest/lowest temperature point can be automatically located |
Correction Settings |
Emissivity, Reflected Temperature, Humidity, Ambient Temperature, Test Distance, Transmittance |
Full-Screen Emissivity Correction |
0.01 to 1.00, built-in common material emissivity table |
Areal Emissivity Correction |
Yes |
Analysis in the Imager |
Yes |
Analysis Software |
SmartView IR |
Supported Languages |
Simplified Chinese/English |
Image Display |
Display |
OLED touchscreen, 170° visual range |
Display Size |
5.5 inches |
Display Contrast |
100000: 1 |
Display Resolution |
1920 × 1080 pixels, 1080P UHD display |